s

At a glance...CML 200/50/3
Size 200 x 50 mm
Cover "Snap-Fit" Alumunium Engages at top

Outlets

Standard Size "Centre Mount" Format

Stock Colours

Grey, Black, White, Stone Beige
Suitable for Category 6 cabling
  • Based on the "Centre Mount" range the "Snap Fit" system utilises an extruded aluminium cover which "Snap-Fits" into position. Ideally suited for use in schools, colleges and universities.
  • Suitable for Category 6 data cabling.
  • The ECD "Snap-fit" covers engage at the top edge of the duct, avoiding the problem of floor coverings obstructing the fitting or removal of the cover.
  • Duct and covers are powder coat finished. Standard colours are Black, White, APO Grey and Stone Beige. Over 50 non-standard colours are available.
  • This product has been examined in accordance with AS 3000 and conforms to A.C.A requirements.

"Easy as ECD"



Suggested Specification
  • The contractor shall allow to supply and install "Electric Cable Duct Systems P/L CML 200/50 "Centre Mount" skirting duct with "Snap-Fit" extruded aluminium cover (200mm x 50mm) surface mounted or as otherwise nominated and as described below.
  • The system will reflect the integrated voice/data cabling requirements of Category 5 & 6 and have ferrous mounting shrouds for both power and voice /data outlets. Outlets shall be standard size Clipsal, HPM or PDL Type.
  • The body of the duct shall be extruded aluminium pre-treated and powder coated to a standard colour (White, APO Grey, Stone Beige, or Black) or as nominated by the architect. The duct cover shall be extruded aluminium pre‑treated, powder coated to match.
  • The system shall be earthed in accordance with AS3000 wiring rules and conform to A.C.A requirements.
  • Bends shall be site mitred to fine tolerances with concealed reinforcing angles riveted in position or alternatively manufactured internal/external bends. Adjacent lengths of duct body shall be splice joined with slide in joiner plates. Slide in stop ends shall be fitted where necessary.
  • Installation shall be performed by experienced duct installers, generally as described on E.C.D "Recommended Installation Procedure" leaflet.

Parts List

Description

Part No

Colour

Duct Body ‑ 3m lengths

CML 200/50

Nominate Colour

Duct Cover ‑ 3m lengths

CML 200 C

Nominate Colour

GPO Mounting Kit only (No GPO)

CML 200/50 K

Nominate Colour

Voice/Data Mounting Kit only (No bakelite supplied)

CML 200/50 VDK

Nominate Colour

Internal Bend

CML 200/50 IB

Nominate Colour

External Bend

CML 200/50 EB

Nominate Colour

Reinforcing Angle (Site mitred bends)

CML 200 RA

n/a

Stop End

CML 200/50 SE

Nominate Colour

Flat Bend Plate

CML 200 FB

n/a

Riser to Skirting Tee

CML 200/50 RT

Nominate Colour

Angled Data Face Plate

VDCAT 6

Nominate Colour
 
ecd cable duct - Sydney info@ecdnsw.com.au Phone: 02 9531 0468
Free joomla templates created by Lonex.