At a glance...CM 200/50
spacerSize 200 x 50

spacerOutlets

Standard Size
"Centre Mount" Format

spacerStock Colours

Grey, Black, White, Stone Beige
spacerSuitable for Category 6 cabling

 

  • A jumbo sized skirting duct designed specifically to accomodate bulk cabling requirements for both power and communications.
  • Suitable for Category 6 data cabling when used with ECD angled data faced plates.
  • The largest skirting duct available, ideally suited for use in "call centres", "info-tech facilities" and "research institutes" .
  • The ECD "Centre Mount" range of skirting duct allows for all outlets to be terminated in the equipment fit-off zone providing an attractive symetrical arrangement in "Centre Mount" format.
  • Ferrous mounting shrouds the full depth of the duct body allow maximum space for outlet termination and positioning of standard size outlets.
  • Duct and covers are powder coat finished. Standard colours are Black, White, APO Grey and Stone Beige. Over 50 non standard colours are available.
  • This product has been examined in accordance with AS 3000 and conforms to A.C.A requirements.
  • Accomodates R.C.D and surge protected outlets without the use of mounting blocks.

"Easy as ECD"

Suggested Specification
  • The contractor shall allow to supply and install "Electric Cable Duct Systems P/L CM 200/50 "Centre Mount" skirting duct (200mm x 50mm) surface mounted or as otherwise nominated and as described below.
  • The system will reflect the integrated voice/data cabling requirements of Category 5 & 6 and have ferrous mounting shrouds for both power and voice /data outlets. Outlets shall be standard size Clipsal, HPM or PDL Type.
  • The body of the duct shall be extruded aluminium pre treated and powder coated to a standard colour (White, APO Grey, Stone Beige, or Black) or as nominated by the architect. The duct cover shall be pre‑treated electro‑galvanised steel, powder coated to match.
  • The system shall be earthed in accordance with AS3000 wiring rules and conform to A.C.A requirements.
  • Bends shall be site mitred to fine tolerances with concealed reinforcing angles riveted in position or alternatively manufactured internal / external bends . Adjacent lengths of duct body shall be splice joined with slide in joiner plates. Slide in stop ends shall be fitted where necessary.
  • Installation shall be performed by experienced duct installers, generally as described on E.C.D "Recommended Installation Procedure" leaflet.

Parts List

Description

Part No

Colour

Duct Body ‑ 3m lengths

CM 200/50

Nominate colour

Duct Cover ‑ 1.2m lengths

CM 200 C

Nominate colour

Vertical Riser Cover ‑ 1.2m lengths

CM200 VRC

Nominate colour

GPO Mounting Kit only (no GPO)

CM 200/50 K

Nominate colour

Voice/Data Mounting Kit only (no bakelite supplied)

CM 200/50 VDK

Nominate colour

Internal Bend

CM 200/50 IB

Nominate colour

External Bend

CM 200/50 EB

Nominate colour

Reinforcing Angle (Site mitred bends)

CM 200 RA

n/a

Stop End

CM 200/50 SE

Nominate colour

Flat Bend Plate

CM 200 FB

n/a
 
ecd cable duct - Sydney info@ecdnsw.com.au Phone: 02 9531 0468
Free joomla templates created by Lonex.