At a glance... CM 125/35
Size 125 x 35

spacerOutlets

Standard Size
"Centre Mount" Format

spacerStock Colours

Grey, Black, White, Stone Beige
spacerSuitable for Category 6 cabling

 

 

  • A modest sized duct, designed to accommodate moderate volumes of power and communication cables. Commonly used in small to medium sized projects or where height restrictions are encounted i.e. Under window frames etc.
  • Suitable for Category 6 data cabling when used with ECD angled data face plates.
  • Also available with alternative "Snap‑fit" extruded aluminium cover for extra protection and a streamlined appearance, Refer to Cat number
    CML 125/35.
  • The ECD "Centre Mount" range of skirting ducts allows for all outlets to be terminated in the equipment fit‑off zone providing an attractive symmetrical arrangement in "centre mount" format.
  • Ferrous mounting shrouds the full depth of the duct body allow maximum space for outlet termination and screening.
  • Accommodates flush mounted standard size outlets.
  • Duct and covers are powder coat finished. Standard colours are Black, White, APO Grey and Stone Beige. Over 50 non‑standard colours are available.
  • This product has been examined in accordance with AS 3000 and conforms to A.C.A. requirements.

"Easy as ECD"


Suggested Specification
  • The contractor shall allow to supply and install "Electric Cable Duct Systems P/L" CM 125/35 "Centre Mount" skirting duct
    (127mm x 35mm) surface mounted or as otherwise nominated and as described below.
  • The system will reflect the integrated voice/data cabling requirements of Category 5 & 6 and have ferrous mounting shrouds for both power and voice /data outlets. Outlets shall be standard size Clipsal, HPM or PDL Type.
  • The body of the duct shall be extruded aluminium pre treated and powder coated to a standard colour (White, APO Grey, Stone Beige, or Black) or as nominated by the architect. The duct cover shall be pre‑treated electro‑galvanised steel, powder coated to match.
  • The system shall be earthed in accordance with AS3000 wiring rules and conform to A.C.A requirements.
  • Bends shall be site mitred to fine tolerances with concealed reinforcing angles riveted in position or alternatively manufactured internal / external bends . Adjacent lengths of duct body shall be splice joined with slide in joiner plates. Slide in stop ends shall be fitted where necessary. The cabling contractor shall retain cables in the duct with custom made cable retainers supplied by the duct manufacturer.
  • Installation shall be performed by experienced duct installers, generally as described on E.C.D "Recommended Installation Procedure" leaflet.

Description

Part No

Colour

Duct Body ‑ 3m lengths

CM 125/35

Nominate colour

Duct Cover ‑ 1.2m lengths

CM 125 C

Nominate colour

Vertical Riser Cover ‑ 3m lengths

CML 125 C

Nominate colour

GPO Mounting Kit only (no GPO)

CM 125/35 K

Nominate colour

Voice/Data Mounting Kit only (no bakelite supplied)

CM 125/35 VDK

Nominate colour

Internal Bend

CM 125/35 IB

Nominate colour

External Bend

CM 125/35 EB

Nominate colour

Reinforcing Angle (Site mitred bends)

CM 125 RA

n/a

Stop End

CM 125/35 SE

Nominate colour

Flat Bend Plate

CM 125 FB

n/a
 
ecd cable duct - Sydney info@ecdnsw.com.au Phone: 02 9531 0468
Free joomla templates created by Lonex.