At a glance... CM 150/50
Size 150 x 50

spacerOutlets

Standard Size
"Centre Mount" Format

spacerStock Colours

Grey, Black, White, Stone Beige
spacerSuitable for Category 6 cabling

 

 


 

  • A larger capacity skirting duct for high volume cabling requirements or where provision is required for future needs.
  • Suitable for Category 6 data cabling when used with ECD angled data face plates.
  • Also available with alternative "Snap-fit" extruded aluminium cover for extra protection and streamline appearance. Refer to Cat. Number CML 150/50.
  • The ECD "Centre Mount range of skirting ducts allows for all outlets to be terminated in the equipment fit‑off zone providing an attractive symmetrical arrangement in "centre mount" format
  • Ferrous mounting shrouds the full depth of the duct body allow maximum space for outlet termination and screening.
  • Accommodates RCD or Surger Protected outlets without the use of mounting blocks.
  • Duct and covers are powder coat finished. Standard colours are Black, White, APO Grey and Stone Beige. Over 50 non‑standard colours are available.
  • This product has been examined in accordance with AS 3000 and conforms to A.C.A. requirements.

"Easy as ECD"


Suggested Specification
  • The contractor shall allow to supply and install "Electric Cable Duct Systems P/L CM 150/50 "Centre Mount" skirting duct (150mm x 50mm) surface mounted or as otherwise nominated and as described below.
  • The system will reflect the integrated voice/data cabling requirements of Category 5 & 6 and have ferrous mounting shrouds for both power and voice /data outlets. Outlets shall be standard size Clipsal, HPM or PDL Type.
  • The body of the duct shall be extruded aluminium pre treated and powder coated to a standard colour (White, APO Grey, Stone Beige, or Black) or as nominated by the architect. The duct cover shall be pre‑treated electro‑galvanised steel, powder coated to match.
  • The system shall be earthed in accordance with AS3000 wiring rules and conform to A.C.A requirements.
  • Bends shall be site mitred to fine tolerances with concealed reinforcing angles riveted in position or alternatively manufactured internal / external bends . Adjacent lengths of duct body shall be splice joined with slide in joiner plates. Slide in stop ends shall be fitted where necessary.
  • Installation shall be performed by experienced duct installers, generally as described on E.C.D "Recommended Installation Procedure" leaflet.

Description

Part No

Colour

Duct Body ‑ 3m lengths

CM 150/50

Nominate colour

Duct Cover ‑ 1.2m lengths

CM 150 C

Nominate colour

Vertical Riser Cover ‑3m lengths

CML 150 C

Nominate colour

GPO Mounting Kit only (no GPO)

CM 150/50 K

Nominate colour

Voice/Data Mounting Kit only (no bakelite supplied)

CM 150/50 VDK

Nominate colour

Internal Bend

CM 150/50 IB

Nominate colour

External Bend

CM 150/50 EB

Nominate colour

Reinforcing Angle (Site mitred bends)

CM 150 RA

n/a

Stop End

CM 150/50 SE

Nominate colour

Flat Bend Plate

CM 150 FB

n/a
 